Less-Invasive Crack Repair for Concrete Floors and Structures


The demonstration will show the repair of cracks in concrete using structural polyurethane injection without pumps, ports or cutting, featuring Roadware 10-Minute Concrete Mender and Easy Injection System. This no cutting method generates almost no dust, making silica dust mitigation much easier.

Objectives

  1. Demonstrate preparation of cracks for repair while reducing silica dust creation and exposure. 
  2. Explain the prevention of micro-fractures caused by cutting and aggressive preparation. 
  3. Demonstrate the injecting of structural polyurethane without pumps or ports. 
  4. Demonstrate bringing cracked slabs back to a pre-cracked condition.