This bundle is for Hard Copies only.
This bundle includes the 110.1 (2016) and 110.3 (2021) Guide Specifications. The documents cover Guide Specifications for Structural Concrete Repair and Guide Specifications for Cementitious Bonded Overlay, respectively.
The intent of this document is to provide objective, standards-based comparison for the
specification, evaluation, and approval of the degree of surface preparation of exposed
conventional reinforcing steel by abrasive media blasting and mechanical hand tool methods.
This guide is designed for use with associated illustrative materials available in digital or
physical form through ICRI.
This bundle includes the 110.1 (2016), 110.2 (2020), 110.3 (2021). 330.2 (2016) Guide Specifications. The documents cover Guide Specifications for Structural Concrete Repair, Epoxy Injection, Guide Specifications for Cementitious Bonded Overlay, and Externally Bonded FRP Fabric Systems for Strengthening Concrete Structures, respectively.
Reported by ACI Committee 562
This latest version of the code was developed to provide design professionals a code for the assessment of damage and deterioration, and the design of appropriate repair and rehabilitation strategies. The code provides minimum requirements for assessment, repair, and rehabilitation of existing structural concrete buildings, members, systems and, where applicable, nonbuilding structures. ACI 562-21 was specifically developed to be incorporated into the International Existing Building Code (IEBC) or to be adopted as a stand-alone code.
This comprehensive book describes the causes, effects, and remedies for concrete wear and failure. It is a practical guide to evaluation of deterioration and its causes, selection of repair methods and materials, surface preparation, and quality assurance of the finished product. Hundreds of illustrations show users how to analyze, maintain, and repair concrete structures for optimal performance and cost-effectiveness.
This guide specification aids the Design Professional in the preparation of technical specifications for inclusion directly into a project manual for the construction of cementitious bonded overlays that are in line with the state-of-the-art materials and methods used in the concrete repair industry. The document provides an outline for developing the three parts of the specification through suggested text, references, and commentary for evaluating alternatives. This specification section must be used with ICRI 110.1, Guide Specifications for Structural Concrete Repairs. Both the printed and PDF copies include a Word document with hidden text for easy modification of text to meet specific cementitious bonded overlay project requirements. PDF version is free to ICRI members when ordered online.
Este lineamiento proporciona una guía sobre la remoción de concreto y los procedimientos para la preparación de la superficie paray la reparación del de concreto deteriorado provocado por la corrosión del acero de refuerzo. Se discuten la geometría de la remoción, la configuración del área de reparación, el proceso de remoción, la preparación del borde, la reparación del refuerzo, la preparación e inspección de la superficie necesarias para las reparaciones durables. Se incluyen consideraciones especiales para la remoción de concreto asociada con la reparación de columnas.
This guideline is intended to provide information for the selection and application of materials
for fluid-applied waterproofing systems to concrete for horizontal pedestrian and vehicular
traffic surfaces.
Concrete is subject to deterioration by a variety of mechanisms. Properly selected and applied
traffic membrane systems can protect concrete from deterioration caused by abrasion, moisture
intrusion, environmental forces (freezing-and-thawing cycling), and chemical attack. This
guideline provides information on the common service conditions, basic review of the properties
of concrete, surface preparation, system designs, and materials used for traffic membranes.
Summarizes the capabilities, operating requirements, and limitations of the various methods used to prepare concrete surfaces for the application of protective sealers, coatings, polymer overlays, and concrete repair. Benchmark profiles are included which provide visual standards for purposes of specification, application, and verification. In this updated version of the guideline you will find; surface retarders and handheld breakers have been added to the surface preparation methods; surface preparation methods have been updated; and a new appendix summarizes considerations for selecting surface preparation methods and describes various test methods used to evaluate the prepared surface. Plus, concrete surface profile (CSP) 10 has been added to reflect a more aggressive CSP used for concrete repair.
This guideline will assist contractors, owners, engineers, architects, and material suppliers in the selection of nondestructive evaluation (NDE) methods for evaluating the condition of concrete structures. NDE can be a very useful method to provide quality control and assurance of repairs and long-term performance monitoring. Considerations in planning and executing an NDE program, including correlating with destructive methods, are discussed in the guideline. Guidance, including a brief synopsis of each method, is presented for selecting which NDE methods are appropriate for the concrete property/condition being assessed.