Skip to main content

Quantity 20-49


On Demand

Duration:
29 Minutes
Format:
Audio and Video
License:
Access for 6 month(s) after purchase.
Short Description:
The Avalon Mall parking facility is a four level above grade structure, consisting of three suspended parking levels (approximately 7,750sq.m. each) and one on-grade parking level connected to the existing mall with a new pedestrian bridge. RJC was the structural engineer of record. During construction of the parking structure extensive cracking of the suspended parking garage slabs was noted at two of the 24 pours. RJC undertook a visual assessment of the parking slabs in question to determine the extent of the noted cracking and determined over 750lin.m. of cracks ranging in size from 0.5mm to 6.5mm in width. Following the visual assessment destructive testing of the concrete was undertaken to determine its in-situ properties as well as to understand the full extent of the cracking.
Base Price:
$25.00
Price with Discount:
$21.25

On Demand

Duration:
30 Minutes
Format:
Audio and Video
License:
Access for 6 month(s) after purchase.
Short Description:
The ACI 562-16 Repair Code is primarily intended for the Licensed Design Professional for providing the requirements necessary for assessing and designing repairs and rehabilitation of existing concrete structures.
Base Price:
$0.00
Price with Discount:
$0.00

On Demand

Duration:
30 Minutes
Format:
Audio and Video
License:
Access for 6 month(s) after purchase.
Short Description:
The Ituango dam is an embankment dam that is currently under construction on the Cauca River in Colombia. The largest hydroelectric power plant in Colombia’s history. Three large diversion tunnels used to divert the water from the river around the construction site during construction collapsed as a result of heavy rainfalls. The nearly completed pump house had to be flooded to accommodate premature water build-up in the reservoir. These tunnels would need to be permanently sealed. “Pre-stoppers” would need to be constructed in place to serve as bulk heads between which would ultimately be excavated and back-filled with concrete to permanently seal the tunnels. Additional to standard anti-washout properties, the grout had to withstand swiftly flowing water and exhibit an extended working time at temperatures above 32 degrees C. A custom grout was developed for this application. In the end, hundreds of grout micropiles were tremied, consuming more than 1,650 tons of grout, to produce...
Base Price:
$25.00
Price with Discount:
$21.25

On Demand

Duration:
34 Minutes
Format:
Audio and Video
License:
Access for 6 month(s) after purchase.
Short Description:
Two projects will be explored in this presentation. The first is a concrete structure which for 20 years was exposed to extreme heat. The second is a structure which was exposed to extreme vibrations. Both these structures were integral parts of manufacturing processes and required limited down time to repair. The questions needing to be answered were: what is the condition of the existing concrete and what are the repair options for these structures. We turned to non-destructive techniques to evaluate these structures. Non-destructive techniques can provide insight into structures when accompanied by experienced engineers and petrographic analysis. Repair options were provided at the end of our evaluation leading to reduced down time and well-planned repairs.
Base Price:
$25.00
Price with Discount:
$21.25

On Demand

Duration:
36 Minutes
Format:
Audio and Video
License:
Access for 6 month(s) after purchase.
Short Description:
Alkali-Silica Reaction (ASR) can cause significant damage to concrete structures including bridges, roadways, airport runways, and nuclear power plants. When reactive aggregates are included in a mix, the presence of moisture initiates a reaction between the alkaline cement paste and reactive amorphous silica. The result is a gel that continues to dilate, which may cause cracks in the concrete mass. A research program was undertaken at the University of Toronto to investigate the effects of ASR on large-scale and small-scale concrete specimens. Several specimens were constructed using reactive (ASR) concrete and non-reactive (regular) concrete, and their short-term and long-term structural and mechanical behavior were compared. In this presentation, we will discuss the results of the research program, will offer best practices to minimize the risk of ASR in concrete during placement, and will propose several strategies for repair of structures that have been degraded due to ASR.
Base Price:
$25.00
Price with Discount:
$21.25

On Demand

Bundle:
Fall Conference Bundle
Duration:
36 Minutes
Format:
Audio and Video
License:
Access for 6 month(s) after purchase.
Short Description:
A significant percentage of repairs are performed during the course of constructing new structures. Once a construction anomaly or error occurs the first concerns are for life safety and schedule impact. A review of the steps necessary to successfully perform repairs and minimize impacts to the ongoing construction. Examples of challenging problems and the traditional and non-traditional solutions to these problems will be discussed.
Base Price:
$25.00
Price with Discount:
$21.25

On Demand

Bundle:
Fall Conference Bundle
Duration:
37 Minutes
Format:
Audio and Video
License:
Access for 6 month(s) after purchase.
Short Description:
Nondestructive testing is often used in conjunction with traditional methods to assess construction, material, or structural deficiencies in new construction. This presentation describes evaluation of unique delamination failures within below-grade, exterior walls of a new subway station. The walls were conventionally reinforced mass concrete cast against a soldier pile and lagging retention system. Shortly after construction, leakage at cracks and joints was observed and injection processes led to delamination of the interior surfaces. The assessment objectives were to determine the extent and cause of near-surface discontinuities and evaluate the structural integrity of the walls. Nondestructive testing included flaw detection using Impulse Response [structural mobility testing] and reinforcement locating using ground-penetrating radar. Sampling and petrographic examinations were conducted to correlate test results with distress conditions and evaluate the in-situ concrete.
Base Price:
$25.00
Price with Discount:
$21.25

On Demand

Duration:
37 Minutes
Format:
Audio and Video
License:
Short Description:
The prestressed beams in the Hampton Roads Bridge Tunnel Approach Spans were fabricated in about 1960 (west bound lane) and 1970 (east bound lane). The spans are 50-ft and 75-ft, respectively. The brackish water environment caused corrosion and failure of the bottom strands and deterioration and spalling of the cover concrete in many beams. A project in 2018 strengthened 30 of the more deteriorated beams as an alternative to posting or replacing the bridges. Carbon fiber composite wrap (CFCW) and external post-tensioning (PT) were used to strengthen the beams. Prior to construction, a PT mockup was done with one 50-ft (flexible filler) and one 75-ft (grout) beam to demonstrate that the contractor had the materials, equipment and staff to successfully do the external PT. This presentation describes the project’s mockups and construction and the anticipated increase in strength to be obtained from application of the CFCW and external PT.
Base Price:
$25.00
Price with Discount:
$21.25

On Demand

Bundle:
Fall Conference Bundle
Duration:
38 Minutes
Format:
Audio and Video
License:
Access for 6 month(s) after purchase.
Short Description:
A follow-on presentation to the discussion of our evaluation of over 1500 tire and lube facilities across the United States that prescribed immediate repairs where necessary, reinforcement where deterioration reduced capacity below acceptable levels and coatings necessary to protect structural steel and structural concrete (i.e. our 2019 Philadelphia presentation). This will be an in-depth presentation of how repairs were specified for (3) specific types of structures. The (3) structure types are exposed structural concrete, composite metal deck and fully reinforced form deck slabs all supported by steel structures and reinforced concrete walls. Presentation will include before, during and completion photos of each project discussed. Again, touch on the evaluation processes to include demand to capacity ratios review, evaluation system and inspection form, triggers to determine when shoring is necessary, calculation of capacities per AISC 360, ACI 318, ACI 562 and local building codes.
Base Price:
$25.00
Price with Discount:
$21.25

On Demand

Duration:
39 Minutes
Format:
Audio and Video
License:
Access for 6 month(s) after purchase.
Short Description:
In June 2016, ACI published ACI 562-16,” Code Requirements for Assessment, Repair and Rehabilitation of Existing Concrete Structures and Commentary”. ACI 562-16 replaces ACI 562-13 as a standard for the repair of existing concrete structures. Significant changes to ACI 562-16 include improvements in terminology for consistency with ISO, ASCE and other documents, inclusion of requirements for level of repair based upon extent of damage present, and revisions to the interface bond provisions. The video will describe the concrete repair code, focusing on key changes made to the code and describe how the code is to be used on concrete repair projects.
Base Price:
$0.00
Price with Discount:
$0.00

Please wait ...