After only six years of service, a 6-foot long narrow piece of concrete spalled off an exposed slab edge of a 680-foot tall high-rise in Texas, and fell 160 feet to the podium below. The spall was attributed to premature corrosion at the drip edge. The building featured approximately 9,200 feet of exposed slab edge over its height. Given the potential risk to safety and property of additional concrete spalls, the Owner requested forensic investigations, which (1) identified other areas with signs of similar distress and (2) determined the underlying problem of low reinforcement cover at the drip edge was pervasive. In response, repair options were developed to address the problem and restore intended durability. Given the building height, difficult exterior-only access, downtown environment, and post-tensioning anchors along the slab edge, the repair design and construction both had unique challenges to consider and overcome.
Price:
$15.00 - $25.00

Not Found
On Demand

Presenters:
Stephen Lucy
Duration:
49 Minutes
Format:
Audio and Video
License:
Access for 6 month(s) after purchase.
Short Description:
Dallas City Hall and Plaza are recognized by many due to the opening scenes of Dallas, the television show. What is less known is that the structure is a significant early example of bonded post-tensioned concrete which was utilized throughout the superstructure and two-story parking garage constructed beneath the plaza. Opened in 1977, the parking garage is a two-way bonded post-tensioned concrete slab with unreinforced drop panels supported by flared circular concrete columns. The garage covers two city blocks, extends under two adjacent multi-lane streets, and supports mature landscaping, pool, fountain, and up to 11’-0” of soil. In 2017, several square feet of a drop panel fell from the structure and subsequent observations found multiple locations of drop panel and column capital failures. A structural investigation including destructive and non-destructive testing, and analysis of the existing structure was undertaken to determine the cause of the failures.
Price:
$15.00 - $25.00

Not Found
On Demand

Presenters:
Eric Williams
Duration:
25 Minutes
Format:
Audio and Video
License:
Access for 6 month(s) after purchase.
Short Description:
Presentation will discuss Vision 2020 (Development, Successes and Challenges) as well as items which still need to be completed. This portion of the presentation will be followed by an overview of the presenter's perspective on the future needs for the concrete repair industry. All attendees will be invited to participate in a workshop to develop a complete list of industry needs (consensus if possible).
Price:
$0.00 - Base Price

More info » Register
Not Found
On Demand

Presenters:
Mr. Matthew Sherman
Duration:
49 Minutes
Format:
Audio and Video
License:
Short Description:
This session will describe the use of tensile pull-off (bond) testing for concrete repairs and bonded overlays. It will provide guidance on applications of the test, industry standards and guidelines, acceptance criteria, proper testing procedures, appropriate equipment, and interpretation and reporting of test results. Bond is important because it relates to structural requirements (e.g. for strengthening and structural repairs) and for durability requirements (e.g. for overlays and cosmetic repairs). Testing of bond is needed to verify that the specified bond requirements have been met and a satisfactory result has been obtained.
Price:
$10.00 - $40.00

Not Found
On Demand

Bundle:
Fall Conference Bundle
Presenters:
Billy D. James, P.E.
Duration:
22 Minutes
Format:
Audio and Video
License:
Access for 6 month(s) after purchase.
Short Description:
Post-tensioned concrete is a strong and durable material for construction of exposed parking structures. These types of structures are also fire resistant, but they can be damaged depending upon the severity of the fire. The structure in this presentation suffered significant fire damage early in its construction. The presentation will cover the discovery and testing methods used to determine the extent of fire damage, and the design of the repairs that were instituted to restore strength and allow construction to continue.
Price:
$15.00 - $25.00

Not Found
On Demand

Presenters:
Mike Tracy
Duration:
43 Minutes
Format:
Audio and Video
License:
Access for 6 month(s) after purchase.
Short Description:
Increasingly, the Construction Industry is being dramatically impacted globally by internal and external forces. These influences range from acute labor and skill shortages, demographic and urbanization shifts, as well as, the Industry’s conversion from analog-based processes to digital workflows. This presentation will overview ten significant trends which are uniquely affecting the Construction Industry, creating both new challenges and opportunities, while transforming the Construction Industry.
Price:
$15.00 - $25.00

Not Found
On Demand

Bundle:
Fall Conference Bundle
Presenters:
Anirudh Goel |  Mr Charles Hammond
Duration:
28 Minutes
Format:
Audio and Video
License:
Access for 6 month(s) after purchase.
Short Description:
The presentation, through case studies, talks about emergency response services for structural issues encountered during construction of new design projects. Among other examples is an eleven story precast parking structure. The contractor observed significant diagonal faulted cracking of L-beams (supporting double-tee sections) near bearing locations, few days after pouring topping slab. In addition, inverted-tee girders were observed to be supported on cracked corbels at other locations. A quick turn around was required to mitigate any immediate life safety hazard posed by the structural distresses and buy time for thorough investigation, non-destructive testing, analyses, and repair design. Another example is a seven story precast parking structure. The structure was under construction and reportedly erected out of plumb. Poor concrete placing practices and poor weld detailing led to widespread cracking in multiple structural elements throughout the structure...
Price:
$15.00 - $25.00

Not Found
On Demand

Bundle:
Fall Conference Bundle
Presenters:
Scott M. Greenhaus
Duration:
1 hour
Format:
Audio and Video
License:
Access for 6 month(s) after purchase.
Short Description:
The iconic construction hard hat, a symbol of pride for the construction worker, has changed very little in 50 years. Developments in the understanding of the causes and prevention of debilitating and often fatal head injuries is leading to a revolutionary change in the way we protect our people from head injuries on the jobsite. The classic hard hat is about to change forever. This presentation will focus on new technology available today to minimize the effects of falls and impacts to the head of the worker. We will also focus on new technologies, already in development, that can further provide protection from head injuries. Industry requirements (OSHA, ANSI) will be reviewed, and the application of worldwide standards (EN) will be discussed and applied to new helmet development and implementation.
Price:
$15.00 - $25.00

Not Found
On Demand

Bundle:
Fall Conference Bundle
Presenters:
Nate Rende
Duration:
37 Minutes
Format:
Audio and Video
License:
Access for 6 month(s) after purchase.
Short Description:
Nondestructive testing is often used in conjunction with traditional methods to assess construction, material, or structural deficiencies in new construction. This presentation describes evaluation of unique delamination failures within below-grade, exterior walls of a new subway station. The walls were conventionally reinforced mass concrete cast against a soldier pile and lagging retention system. Shortly after construction, leakage at cracks and joints was observed and injection processes led to delamination of the interior surfaces. The assessment objectives were to determine the extent and cause of near-surface discontinuities and evaluate the structural integrity of the walls. Nondestructive testing included flaw detection using Impulse Response [structural mobility testing] and reinforcement locating using ground-penetrating radar. Sampling and petrographic examinations were conducted to correlate test results with distress conditions and evaluate the in-situ concrete.
Price:
$15.00 - $25.00

Not Found
On Demand

Presenters:
Nigel Parker
Duration:
29 Minutes
Format:
Audio and Video
License:
Access for 6 month(s) after purchase.
Short Description:
The Avalon Mall parking facility is a four level above grade structure, consisting of three suspended parking levels (approximately 7,750sq.m. each) and one on-grade parking level connected to the existing mall with a new pedestrian bridge. RJC was the structural engineer of record. During construction of the parking structure extensive cracking of the suspended parking garage slabs was noted at two of the 24 pours. RJC undertook a visual assessment of the parking slabs in question to determine the extent of the noted cracking and determined over 750lin.m. of cracks ranging in size from 0.5mm to 6.5mm in width. Following the visual assessment destructive testing of the concrete was undertaken to determine its in-situ properties as well as to understand the full extent of the cracking.